Pollution Flashover Control
DSAN-S2001-(I) Anti-Flashover Coating
Primer-and-topcoat hydrophobic protection for ceramic and glass insulation exposed to pollution and moisture.

Product overview
What it is and where it fits.
DSAN-S2001-(I) is designed to reduce continuous conductive water films on contaminated outdoor insulation surfaces. Suitability depends on the insulator material, pollution environment, surface preparation and application controls.
Selection starts with the substrate, equipment, operating environment and intended application process.
Key technical data
Key performance data for product evaluation and material selection.
| Property | Value | Condition | Standard / source |
|---|---|---|---|
| Water contact angle | >150° | Initial prepared coating surface | Published product information |
| Roll-off angle | <5° | Initial prepared coating surface | Published product information |
| Solids content | 57% | Condition not stated in the source document. | Published product information |
| Surface dry | 30 min | Condition not stated in the source document. | Published product information |
| Through dry | 24 h | Condition not stated in the source document. | Published product information |
| Theoretical spreading rate | 4–5 m²/kg | Calculated value; excludes application loss | Published product information |
| Artificial ageing | 3000 h | Reported as passed; test standard not stated. | Published product information |
| Salt-spray exposure | 1000 h | Reported as passed; test standard not stated. | Published product information |
Technical note: Values are presented with the stated conditions where available. Discuss the intended substrate and operating environment before product selection.
Applications
Typical equipment and surfaces.
Use this list to identify the closest equipment, surface and operating condition.
- 01Line insulators
- 02Bushings
- 03Outdoor electrical equipment
- 04Substation insulation interfaces
Related applications
Start from a comparable equipment or surface problem.
Related references
See the product in a comparable equipment context.
Illustrative visualPower transmissionApplication reference · Hydrophobic surface
Outdoor Insulation Under Contamination Exposure
- Challenge
- Water interaction and contamination on exposed insulation
- Material
- DSAN-S2001 Anti-Flashover Coating
Illustrative visualElectrical equipmentApplication reference · Hydrophobic surface
Outdoor Power Equipment in Wet Conditions
- Challenge
- Rain, humidity and deposited contamination
- Material
- Hydrophobic electrical surface coating
Reference imagePower gridApplication reference · Hydrophobic surface
500 kV Nanhai Substation Reactor Anti-Pollution Coating Application
- Challenge
- Outdoor insulation and equipment surfaces exposed to water and deposited contamination.
- Material
- Hydrophobic anti-pollution surface coating
Technical information
Published information for an initial product discussion.
Review the available product information, application context and related research before discussing technical fit.
- Product information
- Surface wetting data
- Ageing and salt-spray references
- Relevant project cases
Related products
Other relevant material options.

Anti-Condensation Coating
Thin hydrophobic coating for condensation-prone electrical enclosures and insulating components.
View product
Electrical Insulation Coating
High-build insulating coating for component-specific applications under the equipment's electrical design authority.
View productProduct enquiry
Discuss DSAN-S2001-(I) Anti-Flashover Coating.
Tell us the application, substrate, operating environment, development goal or market opportunity.